Appendix I Operator’s Guide
RJS, Minneapolis, MN 002-5572
Appendix I (Computer Mode)
Output Data
When the Computer is enabled during Setup, as an
output device, the data is output in a format that a PC
can receive.
The only output for the D4000 Laser SP is Text Analy-
sis (text) data output
Note:
The D4000 Auto Optic is required for full ISO/ANSI in-
spection and the printable Analog Scan Profile (graph-
ic) data
Figure I-1 (GS1-128 Failure)
Inspector D4000L
Revision A.06
Single Scan Analysis
GS1-128
Bad Mod. Check
AI ( 02)
*F024143417*
C1232321218*
Modck:1 078 Fail
Expect:0 078
D/bility .34 D
-100% Tol. +100%
--------++RARR++
GS1-128 Error
Message
Decodability
Grade (34% / D)
Bar code Width
Deviations Chart